N-9018

Specification
AWS Specification: AWS A5.5 E9018
JIS Specification: N/A
Other Specification: N/A
Description
  • N-9018 is an low hydrogen type electrode for welding higher strength steels with tensile strength in excess of 90,000 PSI
  • Coating is specially formulated to resist moisture pickup under conditions of high heat and humidity
TYPICAL CHEMICAL COMPOSITION OF ALL WELD METAL DEPOSITS (%):

C

Si

Mn

P

S

Ni Cr Mo V

0.054

0.37

1.10

0.023

0.012

1.49 0.07 0.29 0.012

 

TYPICAL MECHANICAL PROPERTIES OF ALL WELD METAL DEPOSITS:
Yield Point
N/mm2 (KSI)
 
Tensile Strength
N/mm2 (KSI)
 
Elongation
%
 
Charpy to V-Notch % at -60°F, J (ft. lbs)
 

580 (84)

671 (97)

25

48

 

SIZE AND RECOMMENDED CURRENT RANGE: AC, DC (+), DC (-)

DIAMETER (mm)

2.6

3.2

4.0

5.0

LENGTH (mm)

350

350

400

400

Current Amp

Flat

55 - 85

90 - 130

135 - 185

190 - 250

Vertical & Overhead

50 - 80

80 - 120

110 - 170

-


Welding Positions: ALL POSITIONS INCLUDING VERTICAL DOWN
Approvals: N/A

NOTE:

The information contained or otherwise referenced herein is presented only as “typical” without guarantee or warranty, and Industrial Welding Corporation expressly disclaims any liability incurred from any reliance thereon. Typical data and test results for mechanical properties, deposit, or electrode composition and other properties were obtained from a weld produced and tested according to prescribed standards and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors, including, but not limited to, weld procedure, plate chemistry and temperature, weldment design, and fabrication methods. Users are cautioned to confirm by qualification testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application.

  • For joining HY-90, HY-80, T-1, and other high tensile strength steels
  • Dry the electrodes at 350-400C for about one hour before use
  • Adopt back step method or strike the arc on a small steel plate to prevent blowholes at the arc starting
  • Keep the arc as short as possible
  • Pre-heat at 50-150C before use