N-7018-W1

Specification
AWS Specification: AWS A5.5 E7018-W1
JIS Specification: N/A
Other Specification: N/A
Description
  • N-7018-W1 is an all position iron powder low hydrogen type electrode that exhibits high crack resistibility and superior notch toughness of depositing weld metal
  • Suitable for welding comparatively thick plates of weather proof steel
TYPICAL CHEMICAL COMPOSITION OF ALL WELD METAL DEPOSITS (%):

C

Si

Mn

Cr

Ni

Cu

0.06

0.41

0.59

0.25

0.36

0.30

 

TYPICAL MECHANICAL PROPERTIES OF ALL WELD METAL DEPOSITS:
Yield Point
N/mm2 (KSI)
 
Tensile Strength
N/mm2 (KSI)
 
Elongation
%
 
Impact Value
°C, J (°F, Ft-Lbs)
 

460  (67)

560  (81)

31

-18°, 142  (0°, 105)

 

SIZE AND RECOMMENDED CURRENT RANGE: AC, DC (+)

DIAMETER (mm)

2.5

3.2

4.0

5.0

LENGTH (mm)

350

350

400

400

Current Amp

Flat

55 - 85

90 - 130

130 - 190

200 - 240

Vertical & Overhead

50 - 80

70 - 110

100 - 170

160 - 210


Welding Positions: ALL POSITIONS
Approvals: N/A

NOTE:

The information contained or otherwise referenced herein is presented only as “typical” without guarantee or warranty, and Industrial Welding Corporation expressly disclaims any liability incurred from any reliance thereon. Typical data and test results for mechanical properties, deposit, or electrode composition and other properties were obtained from a weld produced and tested according to prescribed standards and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors, including, but not limited to, weld procedure, plate chemistry and temperature, weldment design, and fabrication methods. Users are cautioned to confirm by qualification testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application.

  • Welding of 50 kgf/mm2 class high tensile strength weather proof steel of structures, buildings, vehicles, and bridges
  • Dry the electrodes at at 350-400C for 60 minutes before use
  • Adopt back step method or strike the arc on a small steel plate to prevent blowholes at the arc starting
  • Keep the arc as short as possible

about us

Industrial Welding Corporation (IWC) was established in 1982 by Mr. H. Ong Hai who had 25 years of welding industry experience (at that time). Since then, IWC has consistently and successfully earned an excellent ...
Copyright © 2018 Industrial Welding Corporation