N-12 / N-12A

Specification

AWS Specification: AWS A5.1 E6012
JIS Specification: D4313
Other Specification: N/A

Description

 

Application

 

Remarks

  • Pay attention not to exceed the range of recommended currents
  • Welding with excessive current not only lowers X-ray soundness but also causes increase of spatter, under-cut, and insufficient slag covering
  • For ultimate performance, dry the electrodes at 70-100 degrees C for 30-60 minutes before use
  • Excessive moisture absorption lowers usability and may result in porosity
  • Excessive drying before use may result in less penetration and overheating of the electrode
  • For Philippine market only
  • Technical Data

    TYPICAL CHEMICAL COMPOSITION OF ALL WELD METAL DEPOSITS (%):

    C

    Si

    Mn

    P

    S

    0.10

    0.28

    0.40

    0.017

    0.010

     

    TYPICAL MECHANICAL PROPERTIES OF ALL WELD METAL DEPOSITS:
    Yield Point
    N/mm2 (KSI)
     
    Tensile Strength
    N/mm2 (KSI)
     
    Elongation
    %
     
    Impact Value
    °C, J (°F, Ft-Lbs)
     

    430  (62)

    500  (73)

    27

    0°, 85  (32°, 63)

     

    SIZE AND RECOMMENDED CURRENT RANGE: AC OR DC (+)

    DIAMETER (mm)

    2.5

    3.2

    4.0

    5.0

    LENGTH (mm)

    350

    350

    400

    400

    Current Amp

    Flat

    45 - 100

    85 - 130

    110 - 160

    160 - 220

    Vertical & Overhead

    40 - 70

    85 - 130

    100 - 150

    120 - 190


    Welding Positions:

    FLAT, FILLET, VERTICAL UP, HORIZONTAL, OVERHEAD

    Approvals: N/A

    NOTE:

    The information contained or otherwise referenced herein is presented only as “typical” without guarantee or warranty, and Industrial Welding Corporation expressly disclaims any liability incurred from any reliance thereon. Typical data and test results for mechanical properties, deposit, or electrode composition and other properties were obtained from a weld produced and tested according to prescribed standards and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors, including, but not limited to, weld procedure, plate chemistry and temperature, weldment design, and fabrication methods. Users are cautioned to confirm by qualification testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application.