N-6010

Specification

AWS Specification: AWS A5.1 E6010
JIS Specification: D4310
Other Specification: DIN E4343C4

Description

Application

Remarks

  • Use DC reverse polarity (DC+) current
  • Maintain a short to medium arc
  • Hold electrode perpendicularly to work surface and slightly inclined in direction of travel, keeping size of molten pool small
  • Clear each bead well before applying the next
  • Vertical welding can be done starting from the top or the bottom as the work requires
  • For overhead welding, best results are obtained by the multiple beads method
  • Dry the electrodes at 60-70°C for 30 minutes before use
  • Technical Data

    TYPICAL CHEMICAL COMPOSITION OF ALL WELD METAL DEPOSITS (%):

    C

    Si

    Mn

    P

    S

    0.10

    0.20

    0.50

    0.013

    0.012

     

    TYPICAL MECHANICAL PROPERTIES OF ALL WELD METAL DEPOSITS:
    Yield Point
    N/mm2 (KSI)
     
    Tensile Strength
    N/mm2 (KSI)
     
    Elongation
    %
     
    Impact Value
    °C, J (°F, Ft-Lbs)
     

    420  (61)

    500 (73)

    27

    -29°, 85  (-20°, 63)

     

    SIZE AND RECOMMENDED CURRENT RANGE: DC (+)

    DIAMETER (mm)

    2.5

    3.2

    4.0

    5.0

    LENGTH (mm)

    350

    350

    350

    350

    Current Amp

    Flat & Vertical Down

    50 - 80

    80 - 110

    100 – 150 

    140 - 200

    Vertical Up & Overhead

    30 - 70

    50 - 100

    70 - 120

    120 - 180


    Welding Positions: ALL POSITIONS INCLUDING VERTICAL DOWN
    Approvals: ABS

    NOTE:

    The information contained or otherwise referenced herein is presented only as “typical” without guarantee or warranty, and Industrial Welding Corporation expressly disclaims any liability incurred from any reliance thereon. Typical data and test results for mechanical properties, deposit, or electrode composition and other properties were obtained from a weld produced and tested according to prescribed standards and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors, including, but not limited to, weld procedure, plate chemistry and temperature, weldment design, and fabrication methods. Users are cautioned to confirm by qualification testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application.