NC-50

Specification

AWS Specification: AWS A5.15 ENiFe-Cl
JIS Specification: DFC NiFe
Other Specification: DIN 8573: ENiFe-G2

Description

Application

Remarks

  • Remove all traces of paint, grease, oil, rust, and oxides prior to welding
  • Pay particular attention to castings with sand inclusions
  • Use NFG cutting electrodes for the removal of defects and the preparation of cracked sections
  • Generally, small section castings can be welded without preheat. However, it is important that the base metal interpass temperature does not rise above the "hand-hot" level
  • Deposit in short intermittent beads about 25-50mm with frequent interruptions to allow cooling to take place
  • Fill crater at the end of each weld bead
  • Remove all traces of slag remnants before applying the next bead
  • Deposit without weaving and hammer each weld bead (while still hot) to reduce both local stresses and the risk of weld metal cracking
  • Large castings should be heated slowly and uniformly to a temperature in the range of 100 - 300ºC. After welding, the workpiece should be cooled slowly at an even rate.
  • Technical Data

    TYPICAL CHEMICAL COMPOSITION OF ALL WELD METAL DEPOSITS (%):

    C

    Si

    Mn

    Ni

    Fe

    1.18

    0.70

    0.49

    56.80

    Bal.

     

    TYPICAL MECHANICAL PROPERTIES OF ALL WELD METAL DEPOSITS:
    Tensile Strength
    N/mm2 (KSI)
     
    Elongation
    %
     
    Hardness HV (HRB)
     

    480 (70)

    18

    170 - 190 (85 - 90)

     

    SIZE AND RECOMMENDED CURRENT RANGE: AC, DC (+)

    DIAMETER (mm)

    2.5

    3.2

    4.0

    5.0

    LENGTH (mm)

    300

    350

    350

    350

    Current Amp

    50 - 80

    70 - 110

    100 - 140

    130 - 170


    Welding Positions: ALL POSITIONS EXCEPT VERTICAL DOWN
    Approvals: N/A

    NOTE:

    The information contained or otherwise referenced herein is presented only as “typical” without guarantee or warranty, and Industrial Welding Corporation expressly disclaims any liability incurred from any reliance thereon. Typical data and test results for mechanical properties, deposit, or electrode composition and other properties were obtained from a weld produced and tested according to prescribed standards and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors, including, but not limited to, weld procedure, plate chemistry and temperature, weldment design, and fabrication methods. Users are cautioned to confirm by qualification testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application.